1)
The objectives of this Code are as follows (see Appendix A):
-
OS
Safety
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in or adjacent to
the building or facility will be exposed
to an unacceptable risk of injury.
-
OS1
Fire Safety
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in or adjacent to
the building or facility will be exposed
to an unacceptable risk of injury due to fire. The risks of injury
due to fire addressed in this Code are those caused by—
-
OS1.1 -
- fire or explosion occurring
-
OS1.4 -
- fire safety systems failing to function as expected
-
OS2
Structural Safety
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in or adjacent to
the building will be exposed to an unacceptable
risk of injury due to structural failure. The risks of injury due
to structural failure addressed in this Code are those caused by—
-
OS2.1 -
- loads bearing on the building elements that exceed their load-bearing capacity
-
OS3
Safety in Use
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in or adjacent to
the building or facility will be exposed
to an unacceptable risk of injury due to hazards. The risks of injury
due to hazards addressed in this Code are those caused by—
-
OS3.1 -
- tripping, slipping, falling, contact, drowning or collision
-
OS3.2 -
- contact with hot surfaces or substances
-
OS3.4 -
- exposure to hazardous substances
-
OH
Health
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person will be exposed
to an unacceptable risk of illness.
-
OH1
Indoor Conditions
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in the building or facility will be exposed to an unacceptable
risk of illness due to indoor conditions. The risks of illness due
to indoor conditions addressed in this Code are those caused by—
-
OH1.1 -
- inadequate indoor air quality
-
OH2
Sanitation
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, a person in the building or facility will be exposed to an unacceptable
risk of illness due to unsanitary conditions. The risks of illness
due to unsanitary conditions addressed in this Code are those caused
by—
-
OH2.1 -
- exposure to human or domestic waste
-
OH2.2 -
- consumption of contaminated water
-
OH2.3 -
- inadequate facilities for personal hygiene
-
OH2.4 -
- contact with contaminated surfaces
-
OH5
Hazardous Substances Containment
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, the public will be exposed
to an unacceptable risk of illness due to the release of hazardous
substances from the building or facility.
-
OP
Protection of the Building or Facility from Water and Sewage
Damage
-
OP5
Protection of the Building or Facility from Water and Sewage
Damage
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, the building or facility will be exposed to an unacceptable risk of damage due
to the leakage of service water or sewage.
-
OE
Environment
- An objective of this Code is to limit the
probability that, as a result of the design or installation of the plumbing system, the environment will be affected
in an unacceptable manner.
-
OE1
Resources
- An objective of this Code is to limit the probability
that, as a result of the design or installation of the plumbing system, resources will be used in
a manner that will have an unacceptable effect on the environment.
The risks of unacceptable effect on the environment due to use of
resources addressed in this Code are those caused by—
-
OE1.2 -
- excessive use of water