This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.5.3.(3) | Application | Intent |
+ |
Application | Application 1: Combustible cant strips,
roof curbs, nailing strips and similar components used in the installation
of roofing on buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible
construction. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that are required to be of noncombustible
construction, as stated in Sentence 9.10.6.1.(1).
|
Top of Page | |
Intent | Intent 1: To exempt certain combustible materials from the application
of Sentence 3.1.5.1.(1), on the basis that they are deemed to insignificantly
contribute to fire growth and spread. |
Top of Page |