Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.5.4.(4)
++
Application
Application 1: 
Combustible vertical glazing having a flame-spread rating higher than 75 but not more than 150, installed no higher than the second storey in buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible construction, where the aggregate area of glazing is not more than 25% of the wall area of the storey in which it is located and:
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be of noncombustible construction, as stated in Sentence 9.10.6.1.(1).
Top of Page
Intent
Intent 1: 
To exempt certain combustible materials from the requirements of Sentence 3.1.5.4.(3) if certain conditions are met, on the basis that the materials could significantly contribute to fire growth and spread.
Top of Page