Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.5.8.(3) | Application | Intent |
+ |
Application | Application 1: Combustible subfloors
and combustible finished flooring used in flooring
systems for raised platforms formed by wood members more than 50 mm but
not more than 300 mm high applied directly to or set into a noncombustible floor slab, in buildings described
in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible construction. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that are required to be of noncombustible
construction, as stated in Sentence 9.10.6.1.(1).
|
Top of Page | |
Intent | Intent 1: To clarify that certain combustible materials are permitted
in buildings on the basis that the materials are deemed to insignificantly
contribute to fire growth and spread. |
Top of Page |