Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.5.17.(1) | Application | Intent |
+ |
Application | Application 1: Combustible plumbing fixtures,
including wall and ceiling enclosures that form part of plumbing fixtures,
in buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible
construction, where such fixtures are constructed of material having
a flame-spread rating and smoke developed classification
not more than that permitted for the wall surface of the room or space in
which they are installed. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that are required to be of noncombustible
construction, as stated in Sentence 9.10.6.1.(1).
|
Top of Page | |
Intent | Intent 1: To exempt certain combustible materials from the application
of Sentence 3.1.5.1.(1) if certain conditions are met, on the basis
that the materials are deemed to insignificantly contribute to fire growth
and spread. |
Top of Page |