Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.6.3.(2)
OS1OS3OP3
ObjectiveOS1 Fire Safety
Attribution
(a) [F03-OS1.2]
Application
Application 1: 
Spatial separation, from other structures on the same property, of tents and air-supported structures used as buildings described in Sentence 1.3.3.2.(1) of Division A, except as provided in Sentences 3.1.6.3.(3) and (4), which apply when there is no public occupancy and a limited ground area.
Application 2: 
This also applies when tents and air-supported structures are used as buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To exempt such structures from the application of Subsection 3.2.3. if certain conditions are met to provide an acceptable level of protection. This is to limit the probability that:
  • a fire in a tent or air-supported structure will spread into another building on the same property, which could lead to harm to persons in the building, and
  • a fire in a building will spread into a tent or air-supported structure, which could lead to harm to persons in the tent or air-supported structure.