Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.6.3.(4)
+
Application
Application 1: 
Spatial separation of tents from one another, where the tents are used as buildings described in Sentence 1.3.3.2.(1) of Division A and:
  • are not more than 120 m2 in ground area,
  • are located on fair grounds or similar open spaces, and
  • do not create a hazard to the public.
Application 2: 
This also applies when tents are used as buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To exempt tents from the spatial separation requirements of Sentence 3.1.6.3.(1) and Clause 3.1.6.3.(2)(a) if such tents are limited in size, restricted to certain locations and do not pose a hazard to persons nearby.
Top of Page