Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.6.4.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Clearing of the ground enclosed by a tent or air-supported structure, and the clearing of the ground
for not less than 3 m outside such a structure, when the tent
or air-supported structure is used as a building as described in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies when tents and air-supported
structures are used as buildings to which
Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], as stated in Sentence 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability of ignition of combustible materials
and vegetation, which could lead to the spread of fire, which could lead to
harm to persons. Intent 2: To limit the probability that a fire on the ground will
spread to the tent or air-supported structure, which could lead to harm to
persons inside the structure. |