Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.8.3.(3) | Application | Intent |
OS1 | OP1 | OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Continuity of a shaft, including an exit enclosure,
that penetrates a fire separation in buildings described
in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
except as required by Subsection 3.6.3. for a shaft
penetrating a roof assembly.
|
Top of Page | |
Intent | Intent 1: To limit the probability that fire will spread from one
fire compartment to another fire compartment through a shaft, which could
lead to harm to persons in the other fire compartment. |