Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.8.8.(3) | Application | Intent |
+ |
Application | Application 1: Fire dampers in noncombustible ducts that penetrate a horizontal fire separation not required to have a fire-resistance
rating, in buildings described in Sentence 1.3.3.2.(1) of Division A. |
Top of Page | |
Intent | Intent 1: To exempt certain ducts from the application of Sentence 3.1.8.7.(1), which would otherwise require fire dampers, on the basis
that the installation of fire dampers in this case would lead to a higher
level of fire-resistance at the fire damper location than that provided by
the fire separation. |