Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.8.10.(3) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Maximum bottom, side and top clearances of door assemblies
having a fire-protection rating not less than 20
min and used as closures in fire
separations not required to have a fire-resistance
rating more than:
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
|
Top of Page | |
Intent | Intent 1: To override the clearances in NFPA 80 referred to in Sentence 3.1.8.5.(2). This is to limit the probability that fire will spread
through gaps between a door and a door frame, which could lead to damage to
the building on the other side of the fire compartment. |