Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.8.14.(1)
+
Application
Application 1: 
Fixed wired glass assemblies or glass block, installed in conformance with NFPA 80, “Fire Doors and Fire Windows,” used for the protection of openings in fire separations having a fire-resistance rating not more than 1 h.
Exceptions: 
except as stated in Articles 3.1.8.16. and 3.1.8.17. for the separation of exits.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To exempt certain wired glass and glass block assemblies from the application of Sentence 3.1.8.4.(1) if certain conditions are met, on the basis that they provide an acceptable level of protection against the spread of fire.
Top of Page