Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.8.14.(3)
+OS1OP1
ObjectiveOS1 Fire Safety
Attribution
[F04-OS1.2] Applies to portion of Code text: “Glass blocks permitted by Sentence (1) shall be … reinforced with steel reinforcement in each horizontal joint.”
Application
Application 1: 
Glass blocks used for the protection of openings in fire separations having a fire-resistance rating not more than 1 h, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as stated in Articles 3.1.8.16. and 3.1.8.17. for the separation of exits.
Top of Page
Intent
Intent 1: 
To limit the probability that glass block will be weakened in a fire, which could lead to the failure of the opening protection, which could lead to the spread of fire through openings in a fire separation, which could lead to harm to persons on the other side of the fire separation.
Top of Page