Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.9.3.(4)
+
Application
Application 1: 
Combustible totally enclosed raceways that are embedded in a concrete floor slab installed in an assembly required to have a fire-resistance rating where the concrete cover between the raceway and the bottom of the slab is not less than 50 mm, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To exempt certain service equipment from the application of Sentence 3.1.9.2.(1) if certain conditions are met, on the basis that the equipment is deemed to insignificantly contribute to the growth and spread of fire.