Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.9.3.(5)
+
Application
Application 1: 
Combustible outlet boxes installed in an assembly required to have a fire-resistance rating where the opening through the membrane into the box is not more than 0.016 m2, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To exempt certain service equipment from the application of Sentence 3.1.9.2.(1) if certain conditions are met, on the basis that the equipment is deemed to insignificantly contribute to the growth and spread of fire.