Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.9.3.(6)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Offsetting of outlet boxes that penetrate opposite sides of a wall assembly that also forms a fire separation, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To limit the probability that certain service equipment that penetrates wall assemblies--which also form a fire separation--will contribute to the spread of fire through the assemblies, which could lead to a loss of integrity of the fire separation, which could lead to the spread of fire and smoke from one fire compartment to another fire compartment, which could lead to harm to persons in the other fire compartment.