Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.9.4.(5)
+
Application
Application 1: 
Combustible drain piping that penetrates a horizontal fire separation where the piping leads directly from a noncombustible water closet through a concrete floor slab, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To exempt combustible drain piping from the application of Sentences 3.1.9.2.(1) and 3.1.9.4.(3) if certain conditions are met, on the basis that the imposed conditions limit the probability of the spread of fire or smoke.