Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.1.(2)
OP1OS1OP3
ObjectiveOP1 Fire Protection of the Building
Attribution
Application
Application 1: 
Firewalls consisting of two separate wall assemblies each tied to their respective building frame but not to each other, provided each wall assembly is:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To exclude structural members supported on two separate wall assemblies from the requirements of Sentence 3.1.10.1.(1) on the basis that, in the event that one wall collapses, the other wall will not collapse and will provide at least one half of the required fire-resistance rating otherwise required for a firewall.
Intent 2: 
To limit the probability that fire will spread from an adjacent building to the building, which could lead to damage to the building.