Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.1.(3) | Application | Intent |
+ |
Application | Application 1: Firewalls supported on
structural frames of buildings of noncombustible
construction where the supporting frames have a fire-resistance
rating not less than that required for the firewall.
|
Top of Page | |
Intent | Intent 1: To clarify that the continuity of firewalls referred to
in Sentence 3.1.10.3.(1) can include structural frame support if certain
conditions are met. This is to limit the probability of the structural integrity
of the firewall being compromised in fire conditions. |
Top of Page |