Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.1.(3)
+
Application
Application 1: 
Firewalls supported on structural frames of buildings of noncombustible construction where the supporting frames have a fire-resistance rating not less than that required for the firewall.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To clarify that the continuity of firewalls referred to in Sentence 3.1.10.3.(1) can include structural frame support if certain conditions are met. This is to limit the probability of the structural integrity of the firewall being compromised in fire conditions.
Top of Page