Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.5.(1)
+OP1OS1OP3
ObjectiveOP1 Fire Protection of the Building
Attribution
[F03-OP1.2] Applies to portion of Code text: “… the aggregate width of openings shall be not more than 25% of the entire length of the firewall.”
Application
Application 1: 
Aggregate width of openings through a firewall.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability of a large number of openings in a firewall, which could lead to the failure of the protective closures for these openings during a fire, which could lead to the spread of fire from an adjacent building to the building, which could lead to damage to the building.
Intent 2: 
To limit the probability of a large number of openings in a firewall, which could lead to the failure of the integrity of the firewall, which could lead to the spread of fire from an adjacent building to the building, which could lead to damage to the building.