Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.7.(1)
OP1OS1+OP3
Application
Application 1: 
Extension of combustible material across a roof above a firewall that terminates on the underside of a reinforced concrete roof slab in conformance with Sentence 3.1.10.3.(2).
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A, and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To exempt combustible material that extends across the roof above a firewall from the prohibition on such an extension if certain conditions are met that provide an equivalent level of protection. This is to limit the probability that fire will spread from one side of the firewall to the other.