Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.11.5.(2) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Separation of concealed spaces [fire stopping] in
exterior cornices, mansard style roofs, balconies or canopies in which exposed
construction materials within the space have a flame-spread
rating more than 25, at locations where the concealed space extends
across the ends of required vertical fire separations.
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies, as stated in Clause 3.1.5.3.(2)(c),
to the separation into compartments of roof spaces where combustible roof
sheathing and roof sheathing supports are installed above a concrete roof
deck used in the construction of:
|
Top of Page | |
Intent | Intent 1: To limit the probability that certain spaces will not be
separated from certain other parts of the building, which could lead to the
spread of fire within these spaces, which could lead to harm to persons.
Intent 2: To limit the probability that fire stopping material used
to block and separate certain spaces will not remain in place for a certain
minimum time when subjected to fire conditions, which could lead to the spread
of fire within these spaces, which could lead to harm to persons.
Intent 3: To state the application of Article 3.1.11.7.
|