Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.13.2.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Maximum flame-spread rating of interior wall and ceiling finishes, including glazing and skylights, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as provided by:
  • Sentences 3.1.13.2.(2), (3) and (4), which apply to limited areas of wall and ceiling finishes, and to doors within a dwelling unit or in Group A, Division 1 occupancies,
  • Sentence 3.1.13.3.(1), which applies to bathrooms in suites of residential occupancy,
  • Sentence 3.1.13.4.(1), which applies to light diffusers and lenses,
  • Sentences 3.1.13.6.(1) to (5), which apply to public corridors and certain other corridors,
  • Sentence 3.1.13.8.(1), which applies to buildings required to be of noncombustible construction,
  • Sentence 3.1.13.9.(1), which applies to underground walkways, and
  • Sentence 3.1.13.10.(1), which applies to exterior exit passageways.
Application 2: 
This also applies to the maximum flame-spread rating of interior wall and ceiling finishes of buildings regulated by the provisions of Subsection 3.2.6., as stated in Sentence 3.1.13.7.(1).
Exceptions: 
except as provided in:
  • Sentence 3.1.13.7.(2), which applies to sprinklered buildings, other than buildings of Group B major occupancy and elevator cars,
  • Sentence 3.1.13.7.(3), which applies to trim and millwork in certain locations, and
  • Sentence 3.1.13.7.(4), which applies to doors in certain locations.
Top of Page
Intent
Intent 1: 
To limit the probability that certain finishes having an inappropriately high flame-spread property will be used, which could lead to the spread of fire across the exposed surfaces of the finishes, which could lead to harm to persons.
Top of Page