Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.13.2.(2)
+
Application
Application 1: 
Doors that have a flame-spread rating not more than 200, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except:
Application 2: 
This also applies to the maximum flame-spread rating of interior wall, ceiling and floor finishes of buildings regulated by the provisions of Subsection 3.2.6., as stated in Sentence 3.1.13.7.(1).
Exceptions: 
except as provided in:
  • Sentence 3.1.13.7.(2), which applies to sprinklered buildings, other than buildings of Group B major occupancy and elevator cars,
  • Sentence 3.1.13.7.(3), which applies to trim and millwork in certain locations, and
  • Sentence 3.1.13.7.(4), which applies to doors in certain locations.
Top of Page
Intent
Intent 1: 
To exempt certain doors from the application of Sentence 3.1.13.2.(1) and allow a higher maximum flame-spread rating on the basis that the higher rating will not significantly contribute to the spread of flame across the door surface.