Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.13.2.(4)
+
Application
Application 1: 
Interior finish material with a maximum flame-spread rating of 150 for:
  • up to 10% of the total wall area and 10% of the total ceiling area of a wall or ceiling finish that is required by Sentence 3.1.13.2.(1) to have a flame-spread rating less than 150, and
  • up to 25% of the total wall area of lobbies described in Sentence 3.4.4.2.(2).
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to the maximum flame-spread rating of interior wall, ceiling and floor finishes of buildings regulated by the provisions of Subsection 3.2.6., as stated in Sentence 3.1.13.7.(1).
Exceptions: 
except as provided in:
  • Sentence 3.1.13.7.(2), which applies to sprinklered buildings, other than buildings of Group B major occupancy and elevator cars,
  • Sentence 3.1.13.7.(3), which applies to trim and millwork in certain locations, and
  • Sentence 3.1.13.7.(4), which applies to doors in certain locations.
Top of Page
Intent
Intent 1: 
To exempt portions of wall and ceiling finishes from the application of Sentence 3.1.13.2.(1) and allow a higher maximum flame-spread rating, on the basis that these surface portions will not significantly contribute to the spread of flame.
Top of Page