Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.13.6.(1) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Interior wall finish with a maximum flame-spread
rating of 75, in buildings described in Sentence 1.3.3.2.(1), for:
Application 2: This also applies to occupancies in
the corridor, as stated in Sentence 3.1.13.6.(4).
Exceptions:
except as provided in:
|
Top of Page | |
Intent | Intent 1: To limit the probability that interior wall finishes that
have an inappropriately high flame spread property will be used in certain
building locations, which could lead to the spread of fire across the exposed
surfaces of the finishes, which could lead to harm to persons.
Intent 2: To exempt interior wall finishes used in certain locations
from the application of Sentence 3.1.13.2.(1), which would otherwise
allow a higher maximum flame-spread rating, on the basis that a lower flame-spread
rating is needed in these locations to protect persons during evacuation.
|
Top of Page |