Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.13.6.(3)
+
Application
Application 1: 
Flame-spread rating limits specified in Sentences 3.1.13.6.(1) and (2) for corridors referred to in Sentence 3.1.13.6.(1) in which the flame-spread rating is not more than 150.
Application 2: 
This also applies to occupancies in the corridor, as stated in Sentence 3.1.13.6.(4).
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A that are sprinklered throughout.
Top of Page
Intent
Intent 1: 
To exempt interior wall finishes in corridors from the application of Sentences 3.1.13.2.(1), 3.1.13.6.(1) and 3.1.13.6.(2), which would otherwise require certain maximum flame-spread ratings, if certain conditions are met, on the basis that these finishes will not significantly contribute to the spread of flame, and the condition imposed [sprinklering] will control the growth and spread of fire.