Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.13.6.(3) | Application | Intent |
+ |
Application | Application 1: Flame-spread rating limits
specified in Sentences 3.1.13.6.(1) and (2) for corridors referred to in Sentence 3.1.13.6.(1) in
which the flame-spread rating is not more than
150. Application 2: This also applies to occupancies in
the corridor, as stated in Sentence 3.1.13.6.(4). This
applies to buildings described in Sentence 1.3.3.2.(1) of Division A that are sprinklered throughout.
|
Top of Page | |
Intent | Intent 1: To exempt interior wall finishes in corridors from the application
of Sentences 3.1.13.2.(1), 3.1.13.6.(1) and 3.1.13.6.(2), which would otherwise require certain maximum
flame-spread ratings, if certain conditions are met, on the basis that these
finishes will not significantly contribute to the spread of flame, and the
condition imposed [sprinklering] will control the growth and spread of fire.
|
Top of Page |