Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.13.7.(3) | Application | Intent |
+ |
Application | Application 1: Trim and millwork in an exit stairway,
a vestibule to an exit stairway, a lobby described
in Sentence 3.4.4.2.(2), or a corridor not within a suite,
where the trim and millwork have:
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A that are regulated by the provisions
of Subsection 3.2.6.
|
Top of Page | |
Intent | Intent 1: To exempt trim and millwork used in certain locations in
high buildings from the application of Sentence 3.1.13.7.(1) and Article 3.1.13.2., which would otherwise require lower flame-spread ratings
and smoke development classifications, if certain conditions are met, on the
basis that these materials will not significantly contribute to smoke development
or flame spread. |
Top of Page |