Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.2.3.(1) | Application | Intent |
+ | + |
Application | Application 1: Fire protection for loadbearing steel
or concrete members wholly or partly outside a building not
more than 4 storeys in building
height and classified as a Group A, B, C, D or F, Division 3 major occupancy. This applies
to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
|
Top of Page | |
Intent | Intent 1: To exempt from the application of Article 3.2.2.1.,
which relates to fire protection, certain exterior structural members that
are effectively shielded from a fire inside the building, provided they are
shielded from heat radiation in the event of a fire within the building by
construction that will provide the same degree of protection that would be
necessary if the member were located inside the building with the protection
extending on either side of the member a distance equal to the projection
of the member from the face of the wall. |