Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.6.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Fire separation, fire-resistance rating, type of construction and sprinkler requirements for buildings that contain more than one major occupancy.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions: 
except:
  • as exempted in Sentence 3.2.2.8.(1), which applies when:
    • the aggregate area of all major occupancies in a particular Group or Division does not exceed 10% of the floor area on the storey on which they are located, and
    • buildings are not classified as a Group F, Division 1 or Division 2 occupancies,
  • as exempted in Article 3.2.2.7., which applies to superimposed major occupancies, and
  • as required by Article 3.2.2.18. for a storey below a storey that is required to be sprinklered.
Top of Page
Intent
Intent 1: 
To limit the probability that inadequate fire safety features will contribute to the spread of fire or collapse, which could lead to the failure of the integrity of a fire separation or structural element, which could lead to the spread of fire and smoke or collapse, which could lead to harm to persons.