Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.7.(2)
+
Application
Application 1: 
Minimum fire-resistance rating of a floor between two superimposed major occupancies in a portion of a building containing more than one major occupancy.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions: 
except as exempted in Sentence 3.2.2.8.(1), which applies when:
Top of Page
Intent
Intent 1: 
To clarify that the requirements of Subsection 3.2.2., pertaining to the minimum fire-resistance rating of floors for each portion of a building containing a major occupancy, are to be applied to that portion as if the entire building were of that major occupancy.
Intent 2: 
To override the requirement of Sentence 3.2.2.6.(1) which states that the entire building must be constructed in accordance with the most stringent requirements of each of the different major occupancies in the building.