Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.10.(3)
+
Application
Application 1: 
Street access for fire department equipment to a building that has not less than 50% of the building perimeter located within 15 m of the street or streets.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Top of Page
Intent
Intent 1: 
To clarify that a building that has not less than 50% of its perimeter within 15 m of a street or streets is considered to face two streets for the purposes of Subsection 3.2.2.