Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.15.(2)
OS1OP1OS1OP1
ObjectiveOP1 Fire Protection of the Building
Attribution
(b),(c) [F03-OP1.2] [F04-OP1.2,OP1.3]
Application
Application 1: 
Fire-resistance rating and fire separation requirements for a portion of a building that is erected entirely below the adjoining finished ground level and that extends more than one storey below that ground level.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Application 2: 
This also applies to a basement containing more than one storey, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(3).
Top of Page
Intent
Intent 1: 
To limit the probability that loadbearing walls, columns and arches exposed to fire will prematurely fail or collapse, which could lead to the failure or collapse of supported floor or roof assemblies during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to damage to the building.
Intent 2: 
To limit the probability that floor assemblies exposed to fire will prematurely fail or collapse during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to damage to the building.
Intent 3: 
To limit the probability that loadbearing walls, columns and arches exposed to fire will prematurely fail or collapse, which could lead to the failure or collapse of supported floor assemblies, which could lead to the spread of fire from a lower storey of a building to an upper storey or to the exterior during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to damage to the building.
Intent 4: 
To limit the probability that floor assemblies exposed to fire will prematurely fail or collapse, which could lead to the spread of fire from a lower storey of a building to an upper storey or to the exterior of the building during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to damage to the building.