Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.15.(3)
+
Application
Application 1: 
Automatic sprinkler system in a storey that:
  • is immediately below a first storey that is not required to be sprinklered,
  • contains only residential occupancies, and
  • has at least one unobstructed access opening conforming to Sentence 3.2.5.1.(2) for each 15 m of wall length in at least one wall required to face a street.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Application 2: 
This also applies to a basement containing more than 1 storey, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(3).
Top of Page
Intent
Intent 1: 
To exclude a basement used as a residential occupancy from the requirements of Clause 3.2.2.15.(2)(a) pertaining to the installation of an automatic sprinkler system.
Intent 2: 
To expand the application of Sentence 3.2.5.1.(1) to a storey of residential occupancy located immediately below the first storey and that is not required to be sprinklered.