Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.16.(1)
+
Application
Application 1: 
Type of construction of a roof assembly of a building up to 2 storeys in building height that is sprinklered throughout.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Top of Page
Intent
Intent 1: 
To exempt certain buildings from the application of Articles 3.2.2.20., 3.2.2.23., 3.2.2.24., 3.2.2.29., 3.2.2.31., 3.2.2.36., 3.2.2.37., 3.2.2.38., 3.2.2.39., 3.2.2.43., 3.2.2.49., 3.2.2.57., 3.2.2.63., 3.2.2.67., 3.2.2.68., 3.2.2.73., and 3.2.2.75., which would otherwise require the roof assembly to be of noncombustible construction, and permit a roof assembly of heavy timber construction.