Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.2.17.(1) | Application | Intent |
+ |
Application | Application 1: Fire-resistance rating for
a roof assembly above a gymnasium, a swimming pool, an arena, or a rink that
has no part less than 6 m above the main floor or balcony and
carries no loads other than normal roof loads, including permanent access
walks, and ventilating, sound and lighting equipment. This
applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions:
except that the restriction concerning minimum 6 m distance
does not apply to an inclined and stepped floor ascending from the main floor
that is used for seating purposes only.
|
Top of Page | |
Intent | Intent 1: To exempt certain buildings from the application of Articles 3.2.2.25., 3.2.2.30., and 3.2.2.32., which would otherwise require the roof assembly
to have a fire-resistance rating. |