Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.2.24.(2)
+OS1OP1OS1OP1OS1OP1
Application
Application 1: 
Type of construction of a roof assembly and structural members immediately below the roof assembly in a storey in which more than 10% of the area is classified as a Group A, Division 2 major occupancy. This applies in buildings that have no restrictions on building area but are not more than 6 storeys in building height.
This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions: 
except:
  • a storey in which more than 10% of the area is classified as a Group A, Division 2 major occupancy but the building complies with the conditions of Articles 3.2.2.25., 3.2.2.26., 3.2.2.27. or 3.2.2.28.,
  • a storey in which more than 10% of the area is classified as a Group A, Division 2 major occupancy but in addition has more than 10% of the area classified as a major occupancy that has more stringent requirements in accordance with Articles 3.2.2.20. to 3.2.2.23. and 3.2.2.25. to 3.2.2.83., and
  • a storey in which more than 10% of the area is classified as a Group A, Division 2 major occupancy but also has a portion of its floor area used for a Group F, Division 1 or 2 occupancy.
Top of Page
Intent
Intent 1: 
To exempt a heavy timber roof structure and its immediate supports, complying with Article 3.2.2.16., from the requirement for noncombustible construction.
Top of Page