Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.2.35.(3) | Application | Intent |
+ |
Application | Application 1: Construction materials in a storey in
which more than 10% of the area is classified as a Group A, Division 4 major occupancy, that has an occupant
load less than 1 500, and that has a limiting
distance of 6 m or more. This applies in buildings that
have no restrictions on building height or building area. This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To exempt roof assemblies and supporting arches and columns
of combustible construction from the requirement of Sentence 3.2.2.35.(1) that
noncombustible construction be used, on the basis that there is a limit on
the occupant load and that the 6 m limiting distance limits the
probability of fire spreading from another building. |