Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.2.73.(2) | Application | Intent |
OS1 | + | + | OP1 | + | OS1 | OP1 | OS1 | OP1 | OS1 | OP1 |
Attribution |
(b)
|
Application | Application 1: Fire-resistance rating of
a floor assembly for an open-air storey in a storage garage classified as a Group F, Division 3 major occupancy. This applies in buildings that
have no restrictions on building height or building area. This applies to buildings to which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 3].
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To exclude the floor assembly in an open-air storage garage
from the 2 h fire-resistance rating on the basis that a 1
h rating is provided and that the fire load is low and the potential
number of occupants exposed to a fire hazard at any one time is low.
|