Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.2.83.(1) | Application | Intent |
+ | OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution |
[F02-OP1.2]
Applies to portion of Code text: “A building used
as a storage garage with all storeys constructed
as open-air storeys and having no other occupancy above it is permitted to have its floor, wall,
ceiling and roof assemblies constructed without a fire-resistance
rating provided it is: a) of noncombustible
construction…”
|
Application | Application 1: Fire-resistance rating of
floor, wall, ceiling and roof assemblies in a storey in
which more than 10% of the area is classified as a Group F, Division 3 major occupancy. This applies in buildings used
as a storage garage with all storeys constructed
as open-air storeys, having no other occupancy above
it and that is:
This applies to buildings to
which Part 3 applies [see Sentence 1.3.3.2.(1) of Division A for application
of Part 3].
|
Top of Page | |
Intent | Intent 1: To exempt certain buildings from the requirements for a
fire-resistance rating of floor, wall, ceiling and roof assemblies in Articles 3.2.2.73. to 3.2.2.79. if
measures are taken to limit the probability that combustible construction
materials within a storey of a building will be involved in a fire, which
could lead to the growth of fire, which could lead to the spread of fire within
the storey during the time required to achieve occupant safety and for emergency
responders to perform their duties, which could lead to damage to the building.
|