Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.1.(6)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Calculating the area of unprotected openings in an exposing building face, where the surface temperature on the unexposed surface of a wall assembly exceeds the temperature limit of a standard fire test as provided in Article 3.1.7.2., in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to the rating for exposure to fire of exterior walls in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.3.3.(2).
Top of Page
Intent
Intent 1: 
To state how to treat radiation from the hot unexposed wall surface and add an equivalent area in calculating the area of unprotected openings in an exposing building face. This is to limit the probability of the spread of fire from the building to an adjacent building, which could lead to damage to adjacent buildings.