Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.5.(2)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Use of wired glass or glass block as closures required in Sentence 3.2.3.5.(1) for openings in a wall that:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To limit the probability that a closure will be constructed of a material that would not adequately control the spread of fire by means of radiation through exterior openings, which could lead to the spread of fire from the building to an adjacent building during the time required for emergency responders to perform their duties, which could lead to damage to adjacent buildings.
Intent 2: 
To limit the application of Sentence 3.2.3.5.(1) and prohibit the use of wired glass or glass block as closures in openings in certain walls.