Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.3.10.(1) | Application | Intent |
OP3 |
Objective | OP3 Protection of Adjacent Buildings from Fire |
Attribution | |
Application | Application 1: Area of unprotected openings in
an exposing building face in a storage
garage with all storeys constructed as open-air storeys, where the limiting
distance is not less than 3 m. This
applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
|
Top of Page | |
Intent | Intent 1: To exempt open-air storage garages from the requirements
of Sentences 3.2.3.1.(1) and 3.2.3.7.(1) to (6), which would otherwise limit
the area of unprotected openings, and permit unlimited unprotected openings,
on the basis that the fire load of the contents is relatively low, the space
is well ventilated and the limiting distance is not less than 3 m.
These conditions are to limit the probability of the spread of fire from the
garage to an adjacent building, which could lead to damage to adjacent buildings.
|