Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.10.(1)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Area of unprotected openings in an exposing building face in a storage garage with all storeys constructed as open-air storeys, where the limiting distance is not less than 3 m.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To exempt open-air storage garages from the requirements of Sentences 3.2.3.1.(1) and 3.2.3.7.(1) to (6), which would otherwise limit the area of unprotected openings, and permit unlimited unprotected openings, on the basis that the fire load of the contents is relatively low, the space is well ventilated and the limiting distance is not less than 3 m. These conditions are to limit the probability of the spread of fire from the garage to an adjacent building, which could lead to damage to adjacent buildings.