Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.13.(2)
+
Application
Application 1: 
Protection of openings in the exterior wall of a building, where:
  • an unenclosed exterior exit stair or ramp could be exposed to fire from the openings in the exterior wall of the building it serves, and
  • the opening in the exterior wall of the building is within 3 m horizontally and:
    • less than 10 m below the exit stair or ramp, or
    • less than 5 m above the exit stair or ramp.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To state the application of Sentence 3.2.3.13.(4).