Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.16.(3)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Soffits, and any opening in the soffits or other surface of the projection located within 2 500 mm of a window or door opening, where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Top of Page
Intent
Intent 1: 
To limit the application of Sentence 3.2.3.16.(1) by excluding eaves overhangs [soffits] if certain conditions are met [eaves overhangs are completely separated from the remainder of the attic or roof space by fire stopping]. This is to limit the probability of the spread of fire from a suite or patient's sleeping room to a common attic or roof space through openings in the eaves overhangs, which could lead to the spread of fire through the common attic or roof space to other suites or patients' sleeping rooms, which could lead to harm to persons.