Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.3.17.(3) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Canopies separating openings between storeys in
the exterior wall of a building, where:
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to the protection of openings with combustible vertical glazing, as stated in Clause 3.1.5.4.(4)(b).
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 3.2.3.17.(1),
which would otherwise require a canopy, if certain conditions are met [the
building is sprinklered throughout]. This [the sprinklering] is to limit the
probability of the spread of fire from one storey to the storey above through
openings in the exterior wall during the time required to achieve occupant
safety and for emergency responders to perform their duties, which could lead
to harm to persons in the storey above. |