Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.19.(2)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Combustibility of construction of [aboveground] walkways connected to buildings required to be of noncombustible construction.
Exceptions: 
except as exempted in Sentence 3.2.3.20.(2), which applies to a walkway at ground level that has 50% of its enclosing walls open to the outdoors.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to bridges between buildings or balconies used as a horizontal exit, as stated in Sentence 3.4.6.9.(6).
Application 3: 
This also applies to buildings to which Part 9 applies, as stated in Sentence 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that materials used for the construction of the walkways will contribute to the growth and spread of fire, which could lead to the spread of fire from one building to the adjacent building connected by means of the walkway, which could lead to damage to the connected building.