Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.2.6.5.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Elevators for use by firefighters. This
applies to high buildings, as defined in Sentence 3.2.6.1.(1):
|
Top of Page | |
Intent | Intent 1: To limit the probability that an elevator suitable for use
by firefighters will not be available during the time required to achieve
occupant safety and for emergency responders to perform their duties, which
could lead to delays or inefficiencies in fire emergency response operations,
which could lead to:
Intent 2: To state the application of Sentences 3.2.6.5.(2) to (6) for
requirements regarding firefighters' elevators. |
Top of Page |