Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.6.6.(3)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Identification and type of windows used for the venting required by Sentence 3.2.6.6.(1) [venting floor areas to the outdoors].
This applies to high buildings, as defined in Sentence 3.2.6.1.(1):
Top of Page
Intent
Intent 1: 
To limit the probability of excessive delays in locating vent windows in a fire situation, which could lead to delays in the opening of the windows, which could lead to the buildup of smoke on floor areas, which could lead to delays or inefficiencies in fire emergency response operations, which could lead to:
  • the spread of fire, which could lead to harm to persons, including emergency responders, and
  • delays in evacuation or moving to a safe place, which could lead to harm to persons.
Intent 2: 
To clarify that windows used for venting are to be of the openable type, on the basis that if fixed windows were permitted, their breakage [by firefighters for venting purposes] could endanger persons below.