Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.8.2.(2)
+
Application
Application 1: 
Openings through a horizontal fire separation for vehicular ramps in a storage garage.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where there are:
  • openings through floors that are not protected by shafts or closures, as stated in Sentence 9.10.1.2.(6), or
  • interconnected floor spaces, as stated in Sentence 9.10.9.5.(1).
Exceptions: 
except as exempted in:
Top of Page
Intent
Intent 1: 
To exempt openings through a horizontal fire separation for vehicular ramps in a storage garage from the requirements of Subsection 3.2.8. [specifically Sentence 3.2.8.1.(1) and Articles 3.2.8.3. to 3.2.8.9.], which would otherwise require a vertical fire separation or certain fire protection measures, on the basis that fire risks are minimized and are unlikely to endanger occupants of the building.
Top of Page